{"id":569,"date":"2023-03-27T11:53:55","date_gmt":"2023-03-27T11:53:55","guid":{"rendered":"https:\/\/old.lindhautomation.com\/?post_type=product&#038;p=569"},"modified":"2023-10-18T17:16:49","modified_gmt":"2023-10-18T17:16:49","slug":"emcheck-lsmz-i","status":"publish","type":"product","link":"https:\/\/old.lindhautomation.com\/sv\/produkt\/emcheck-lsmz-i\/","title":{"rendered":"EMCheck LSMZ I"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_breadcrumb _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_breadcrumb][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; min_height=&#8221;666.1px&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_images _builder_version=&#8221;4.20.2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_images][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_title _builder_version=&#8221;4.20.2&#8243; hover_enabled=&#8221;0&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; header_font=&#8221;|700|||||||&#8221; sticky_enabled=&#8221;0&#8243;][\/et_pb_wc_title][et_pb_wc_meta _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;-5px||-8px|||&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_meta][et_pb_wc_price _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;0px|||||&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][et_pb_wc_price _builder_version=&#8221;4.16&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][et_pb_wc_price _builder_version=&#8221;4.16&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][et_pb_wc_add_to_cart _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;-12px||-3px|||&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_add_to_cart][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; header_5_line_height=&#8221;1.2em&#8221; transform_translate=&#8221;4px|5px&#8221; min_height=&#8221;197px&#8221; custom_margin=&#8221;-25px||2px|||&#8221; custom_padding=&#8221;0px||0px|||&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; text_line_height=&#8221;1.3em&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p class=\"product-title\"><span style=\"color: #333333;\"><strong>Item # 122010005<\/strong> &#8211; EMCheck LSMZ I | EMC &#8211; Measuring clamp for leakage current<\/span><\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|600|||||||&#8221; text_font_size=&#8221;15px&#8221; text_line_height=&#8221;1.6em&#8221; background_color=&#8221;rgba(0,145,242,0.12)&#8221; transform_translate=&#8221;2px|-3px&#8221; min_height=&#8221;79px&#8221; custom_margin=&#8221;-124px||-4px||false|false&#8221; custom_padding=&#8221;26px|16px|0px||false|false&#8221; border_radii=&#8221;on|11px|11px|11px|11px&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul class=\"cf normal-list\">\n<li><em><span style=\"color: #000000;\">Measuring leakage and shielding currents<\/span><\/em><\/li>\n<li><em><span style=\"color: #000000;\">Adjustable measuring range<\/span><\/em><\/li>\n<li><em><span style=\"color: #000000;\">Localizing insulation faults and unwanted shutdown of earth-leakage circuit breakers<\/span><\/em><\/li>\n<li><em><span style=\"color: #000000;\">All the features of a multimeter clamp<\/span><\/em><\/li>\n<li><em><span style=\"color: #000000;\">Continuous measurements by hold functions<\/span><\/em><\/li>\n<li><em><span style=\"color: #000000;\">Convenient measuring in unfavorable installation locations<\/span><\/em><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;mailto:brian@old.lindhautomation.com&#8221; url_new_window=&#8221;on&#8221; button_text=&#8221;Request a Quote&#8221; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; text_line_height=&#8221;1em&#8221; transform_translate=&#8221;0px|4px&#8221; custom_padding=&#8221;17px||0px|||&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><span style=\"font-size: large;\"><strong><span style=\"color: #333333;\">Need assistance?<\/span><\/strong><\/span><\/p>\n<p><span style=\"color: #333333; font-size: large;\"><strong><\/strong><\/span><\/p>\n<p><span style=\"font-size: large;\">Call: <strong><span style=\"color: #003366;\">+46 (0)40 636 8038<\/span><\/strong>\u00a0<\/span><\/p>\n<p><span style=\"font-size: large;\">Email: \u00a0<span style=\"text-decoration: underline; color: #003366;\"><strong><span lang=\"en-US\"><a href=\"mailto:brian@old.lindhautomation.com\" target=\"_blank\" rel=\"noopener noreferrer\" data-auth=\"NotApplicable\" data-safelink=\"true\" data-linkindex=\"3\" style=\"color: #003366;\"><span lang=\"sv\">brian@old.lindhautomation.com<\/span><\/a><\/span><\/strong><\/span><\/span><\/p>\n<p>[\/et_pb_text][et_pb_wc_price _builder_version=&#8221;4.16&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; width=&#8221;100%&#8221; custom_padding=&#8221;0px||0px|||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; transform_translate=&#8221;4px|-86px&#8221; min_height=&#8221;49px&#8221; custom_margin=&#8221;111px||89px|||&#8221; custom_padding=&#8221;10px||5px|||&#8221; hover_enabled=&#8221;0&#8243; locked=&#8221;off&#8221; inline_fonts=&#8221;Verdana&#8221; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<h2 style=\"text-align: center;\"><strong><span style=\"text-decoration: underline;\"><em><\/em><\/span><\/strong><\/h2>\n<h2 style=\"text-align: center;\"><strong><span style=\"text-decoration: underline;\"><em>Measure and Avoid Electro Magnetic Shield Currents<\/em><\/span><\/strong><\/h2>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\"><\/span><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\"><\/span><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\">Often in industrial data communication, the reason for sporadic disturbances is caused by high-frequency shield currents. By measuring the compensating currents over the data line shield, it becomes clear that the Fieldbus network is not the reason for failure problems. It is critical to find out what caused the failure and take countermeasures.<\/span><\/span><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\"><\/span><\/span><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\"><\/span><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800;\">The leakage current clamp <span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\"><strong>EMCheck\u00ae LSMZ I <\/strong>is especially designed for the measuring of leakage and shield currents in the frequency band of 50\/60 Hz as well as 5 Hz \u2013 1 kHz. The adjustable measuring range is arranged in levels from 30 \u03bcA &#8211; 100 A, whereupon the lower range is of special interest for the shield current measurement of the data cable.<\/span><\/span><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\">The <strong>EMCheck\u00ae LSMZ I<\/strong> features a large jaw opening, 2.8 cm, so that the cable can easily pass-through for convenient measurements even in unfavorable installation situations. It is possible to perform permanent measurements, such as maximum currents, by using the hold function.<\/span><\/span><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\"><\/span><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\">Based on our experiences at Indu-Sol, a shield current of &lt;40mA has proven to be adequate regardless of the machine specifications. In the case of larger shield and leakage currents, additional actions have to take place to improve the equipotential bonding or eliminate the source of interference.<\/span><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #2e3800; font-family: Verdana;\"><span style=\"font-size: small;\">The official value for the maximum electrical conductivity of a screen is 150 mA, and anything beyond that will lead to a decrease in the shielding effect and electrical overload of the devices. The limit value for equipotential bonding conductors is (for touch protection reasons) at 300 mA. Protective conductors routed within a cable may carry a maximum of 5% of the flowing phase current.<\/span><\/span><\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-124px||2px|||&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; text_font_size=&#8221;27px&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p style=\"text-align: center;\"><span style=\"text-decoration: underline; color: #333333;\"><strong>PDF Data Sheet<\/strong><\/span><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/old.lindhautomation.com\/wp-content\/uploads\/2023\/03\/LSMZ_I.jpg&#8221; title_text=&#8221;LSMZ_I&#8221; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-112px|||||&#8221; border_width_all=&#8221;2px&#8221; border_color_all=&#8221;#2E3800&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; min_height=&#8221;1060.9px&#8221; custom_margin=&#8221;-51px|auto||auto||&#8221; custom_padding=&#8221;116px|||||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_upsells _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_upsells][et_pb_wc_related_products include_categories=&#8221;44&#8243; _builder_version=&#8221;4.20.2&#8243; custom_margin=&#8221;-41px|||||&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_related_products][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Item # 122010005 &#8211; EMCheck LSMZ I | EMC &#8211; Measuring clamp for leakage current Measuring leakage and shielding currents Adjustable measuring range Localizing insulation faults and unwanted shutdown of earth-leakage circuit breakers All the features of a multimeter clamp Continuous measurements by hold functions Convenient measuring in unfavorable installation locations Need assistance? Call: +46 [&hellip;]<\/p>\n","protected":false},"featured_media":965,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"<a id=\"et_pb_toggle_builder\" class=\"button button-primary button-large et_pb_ready\" href=\"https:\/\/old.lindhautomation.com\/wp-admin\/post-new.php?post_type=product#\" data-builder=\"Use The Divi Builder\" data-editor=\"Return To Standard Editor\">Use The Divi Builder<\/a>","_et_gb_content_width":""},"product_brand":[],"product_cat":[66,55,44],"product_tag":[],"class_list":{"0":"post-569","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-all-products","7":"product_cat-diagnostic-tools","8":"product_cat-emcheck","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product\/569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/comments?post=569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/media\/965"}],"wp:attachment":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/media?parent=569"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product_brand?post=569"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product_cat?post=569"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product_tag?post=569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}