{"id":663,"date":"2023-04-03T13:43:01","date_gmt":"2023-04-03T13:43:01","guid":{"rendered":"https:\/\/old.lindhautomation.com\/?post_type=product&#038;p=663"},"modified":"2023-10-18T17:16:45","modified_gmt":"2023-10-18T17:16:45","slug":"emcheck-mwmz-ii","status":"publish","type":"product","link":"https:\/\/old.lindhautomation.com\/sv\/produkt\/emcheck-mwmz-ii\/","title":{"rendered":"EMCheck\u00ae MWMZ II"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_breadcrumb _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_breadcrumb][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; min_height=&#8221;666.1px&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_images _builder_version=&#8221;4.20.2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_images][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_title _builder_version=&#8221;4.20.2&#8243; hover_enabled=&#8221;0&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; header_font=&#8221;|700|||||||&#8221; sticky_enabled=&#8221;0&#8243;][\/et_pb_wc_title][et_pb_wc_meta _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;-5px||-8px|||&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_meta][et_pb_wc_price _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;0px|||||&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][et_pb_wc_price _builder_version=&#8221;4.16&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][et_pb_wc_price _builder_version=&#8221;4.16&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][et_pb_wc_add_to_cart _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;-12px||-3px|||&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_add_to_cart][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; header_5_line_height=&#8221;1.2em&#8221; transform_translate=&#8221;4px|5px&#8221; min_height=&#8221;197px&#8221; custom_margin=&#8221;-15px||2px|||&#8221; custom_padding=&#8221;0px||0px|||&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; text_line_height=&#8221;1.3em&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p class=\"product-title\"><span style=\"color: #333333;\"><strong>Item # 122010010<\/strong> &#8211; EMCheck MWMZ II | EMC &#8211; Measuring clamp for equipotential bondings<\/span><\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|600|||||||&#8221; text_font_size=&#8221;15px&#8221; text_line_height=&#8221;1.6em&#8221; background_color=&#8221;rgba(0,145,242,0.12)&#8221; transform_translate=&#8221;2px|-3px&#8221; min_height=&#8221;79px&#8221; custom_margin=&#8221;-123px||-3px||false|false&#8221; custom_padding=&#8221;19px|16px|0px||false|false&#8221; border_radii=&#8221;on|11px|11px|11px|11px&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul class=\"cf normal-list\">\n<li><span style=\"color: #2e3800;\"><em>Measuring of earth loop resistance and earth loop inductivity<\/em><\/span><\/li>\n<li><span style=\"color: #2e3800;\"><em>First-time: Display of contact voltage<\/em><\/span><\/li>\n<li><span style=\"color: #2e3800;\"><em>Alert when detecting a dangerous voltage<\/em><\/span><\/li>\n<li><span style=\"color: #2e3800;\"><em>Recording of up to 300 measurements including time stamp<\/em><\/span><\/li>\n<li><span style=\"color: #2e3800;\"><em>Easy handling to keep the clamp open<\/em><\/span><\/li>\n<li><span style=\"color: #2e3800;\"><em>Good visibility of all displayed data via OLED display<\/em><\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_button button_url=&#8221;mailto:brian@old.lindhautomation.com&#8221; url_new_window=&#8221;on&#8221; button_text=&#8221;Request a Quote&#8221; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; text_line_height=&#8221;1em&#8221; transform_translate=&#8221;0px|4px&#8221; custom_padding=&#8221;17px||0px|||&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><span style=\"font-size: large;\"><strong><span style=\"color: #333333;\">Need assistance?<\/span><\/strong><\/span><\/p>\n<p><span style=\"color: #333333; font-size: large;\"><strong><\/strong><\/span><\/p>\n<p><span style=\"font-size: large;\">Call: <strong><span style=\"color: #003366;\">+46 (0)40 636 8038<\/span><\/strong>\u00a0<\/span><\/p>\n<p><span style=\"font-size: large;\">Email: \u00a0<span style=\"text-decoration: underline; color: #003366;\"><strong><span lang=\"en-US\"><a href=\"mailto:brian@old.lindhautomation.com\" target=\"_blank\" rel=\"noopener noreferrer\" data-auth=\"NotApplicable\" data-safelink=\"true\" data-linkindex=\"3\" style=\"color: #003366;\"><span lang=\"sv\">brian@old.lindhautomation.com<\/span><\/a><\/span><\/strong><\/span><\/span><\/p>\n<p>[\/et_pb_text][et_pb_wc_price _builder_version=&#8221;4.16&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_price][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; width=&#8221;100%&#8221; custom_padding=&#8221;0px||0px|||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; transform_translate=&#8221;4px|-4px&#8221; min_height=&#8221;97px&#8221; custom_margin=&#8221;12px||25px|||&#8221; custom_padding=&#8221;0px||5px|||&#8221; hover_enabled=&#8221;0&#8243; locked=&#8221;off&#8221; inline_fonts=&#8221;Verdana&#8221; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<div class=\"et_pb_all_tabs\"><\/div>\n<div class=\"et_pb_all_tabs\">\n<div class=\"et_fb_editing_enabled et-module-3c6cb684-e8cb-4e2b-8fad-86c13cc980cd et_pb_tab ui-sortable et_pb_tab_0 et-animated--vb clearfix et_pb_active_content\" data-address=\"0.3.0.0.0\" dynamic=\"[object Object]\" parent_slug=\"et_pb_tabs\" theme_builder_suffix=\"\" wp_editor_suffix=\"\" wrapper_settings=\"[object Object]\" _key=\"3c6cb684-e8cb-4e2b-8fad-86c13cc980cd\" style=\"z-index: 1; display: block; opacity: 1;\">\n<div class=\"et_pb_tab_content\">\n<div data-shortcode-id=\"0.3.0.0.0-1689580695637\" data-quickaccess-id=\"body-body\" data-quickaccess-editable=\"yes\" class=\"et-fb-popover-tinymce\">\n<div class=\"mce-content-body\" contenteditable=\"true\" style=\"position: relative;\">\n<h2 style=\"text-align: center;\"><span style=\"text-decoration: underline;\"><strong><em>Measuring Equipotential <\/em><\/strong><\/span><span style=\"text-decoration: underline;\"><strong><em>Bonding Interruption-free!<\/em><\/strong><\/span><\/h2>\n<p><span style=\"text-decoration: underline;\"><strong><em><\/em><\/strong><\/span><\/p>\n<h3 class=\"subheadline\"><\/h3>\n<p><span style=\"color: #2e3800;\">From the perspective of automation technology the function of the equipotential bonding is not put into question because the functionality is presumed and the points of contact are mostly seen in the low voltage system. However, in the meantime it was exposed that a secure and solid working communication network, including the bus system, is related with the function of the equipotential bonding. <a href=\"https:\/\/www.indu-sol.com\/en\/support\/glossary\/vagabonding-currents\/\" style=\"color: #2e3800;\" target=\"_blank\" rel=\"noopener\">Straying currents<\/a>\u00a0and currents of higher frequency which are often caused by frequency converters, mostly use the shield of our data cable as return current flow instead of the intended equipotential bonding system.<\/span><\/p>\n<p><span style=\"font-family: Verdana; color: #2e3800;\">Just relying on gut feeling, or making intuitive judgements about the quality of existing shielding and earthing measures is rarely a good idea. The only way to ensure good equipotential bonding is proof by measurement. The mesh resistance measuring clamp <strong>EMCheck<sup>\u00ae<\/sup> MWMZ II<\/strong> is the right tool for this purpose. In this way, you meet the requirements of DIN EN 50310, which is cited in the new guideline\u00a0<em>&#8220;Functional potential equalization and shielding of PROFIBUS and PROFINET&#8221;<\/em> &#8211; from the World Association PROFIBUS &amp; PROFINET International (PI).<\/span><\/p>\n<p><span style=\"font-family: Verdana; color: #2e3800;\"><strong>EMCheck\u00ae MWMZ II<\/strong> consists of two coils. The first coil induces a voltage of a defined level and with a defined frequency of 2083 Hz. The second coil measures the current induced by coil one in the set frequency range. The ratio of these two values is used to determine and display the alternating current resistance (impedance). The measurement is made without any interruption and can also be performed on conductors which already carry currents during their normal operation.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-8px||2px|||&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; text_font_size=&#8221;27px&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p style=\"text-align: center;\"><span style=\"text-decoration: underline; color: #333333;\"><strong>PDF Data Sheet<\/strong><\/span><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/old.lindhautomation.com\/wp-content\/uploads\/2023\/07\/EmCheck_MWMZ_II.jpg&#8221; title_text=&#8221;EmCheck_MWMZ_II&#8221; _builder_version=&#8221;4.20.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-112px|||||&#8221; border_width_all=&#8221;2px&#8221; border_color_all=&#8221;#2E3800&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; min_height=&#8221;1060.9px&#8221; custom_margin=&#8221;-51px|auto||auto||&#8221; custom_padding=&#8221;133px|||||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_upsells _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_upsells][et_pb_wc_related_products include_categories=&#8221;44&#8243; _builder_version=&#8221;4.20.2&#8243; custom_margin=&#8221;-41px|||||&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_wc_related_products][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Item # 122010010 &#8211; EMCheck MWMZ II | EMC &#8211; Measuring clamp for equipotential bondings Measuring of earth loop resistance and earth loop inductivity First-time: Display of contact voltage Alert when detecting a dangerous voltage Recording of up to 300 measurements including time stamp Easy handling to keep the clamp open Good visibility of all [&hellip;]<\/p>\n","protected":false},"featured_media":664,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[66,55,44],"product_tag":[],"class_list":{"0":"post-663","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-all-products","7":"product_cat-diagnostic-tools","8":"product_cat-emcheck","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product\/663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/comments?post=663"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/media\/664"}],"wp:attachment":[{"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/media?parent=663"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product_brand?post=663"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product_cat?post=663"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/old.lindhautomation.com\/sv\/wp-json\/wp\/v2\/product_tag?post=663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}